Furnace Vent Blocked by Snow or Ice in Ottawa?

After a heavy snowfall or a deep freeze, a high-efficiency furnace can shut itself off because the plastic pipes on the side of the house are buried or iced over. Here is why that happens, what you can safely do, and when to call.

Why high-efficiency furnaces vent through the wall

A modern condensing gas furnace squeezes extra heat out of the exhaust, which cools the flue gases enough for the water vapour in them to condense. Natural Resources Canada explains that the condensate is piped to a floor drain or a condensate pump, and that a chimney is not needed. The gases leave the house through an approved plastic pipe, usually out a side wall. Many systems have two pipes: one to bring in combustion air and one to carry the exhaust out.

That design is efficient, and it is also exposed to Ottawa weather. The pipes sit close to the ground on an outside wall, where drifting snow, a plow bank, or ice can cover them. Our furnace and heating page flags this directly: after a big snowfall or a drift, check that the intake and exhaust pipes are clear — a blocked pipe is a common reason a furnace shuts itself off.

Why the furnace stops instead of “pushing through”

A gas furnace needs a clear path for exhaust and, on most high-efficiency models, a clear path for incoming combustion air. If either pipe is blocked, the furnace is designed to shut down rather than run unsafely. You may get no heat, heat that starts and then stops, or a furnace that tries to start, fails, and waits. It often shows up during or right after a storm, or after a wind has piled snow against that wall.

Natural Resources Canada says to keep the outside vent terminal free from obstructions, including ice, and to make sure the pipe always slopes upwards from the appliance to the outside. It also says to look at the vent piping and call a service person if you see cracking or shifting pipes. Health Canada’s carbon monoxide guidance is just as plain: inspect exhaust vents during and after snowstorms to make sure they are not blocked with ice, snow or debris, and do this for the furnace, the dryer, the fireplace and any other appliance that vents outside.

Safety first. If you smell gas (a rotten-egg smell), leave the house right away and call Enbridge Gas at 1-866-763-5427 or 911 from outside. If your carbon monoxide alarm goes off, get everyone outside and call 911.

What you can safely do yourself

If you do not smell gas and the carbon monoxide alarm has not gone off, you can do a careful outdoor check:

  • From the ground, find the plastic pipe or pipes on the side of the house. There may be two close together, or a combined terminal.
  • Gently clear loose snow from around and below the openings, so they can breathe again. A wide path is better than a narrow hole, because the next drift can refill a small gap.
  • Do not hit, pry or chip at the pipes with a shovel or ice tool. They are part of a sealed vent system. Natural Resources Canada says to call a service person if you see cracking or shifting pipes — which is exactly what rough clearing can cause.
  • If the opening is iced solid, or you cannot reach it safely from the ground, stop and call us. Do not climb on a snowbank or a ladder in a storm to get at it.

Once the openings are clear, the furnace may restart on its own, or you may need to reset it at the thermostat. If it starts and then shuts off again, or it will not stay running, treat that as a service call rather than a second round of digging.

For a longer list of no-heat checks — thermostat, breaker, filter, and when to stop troubleshooting — see our post Furnace not working? 7 checks before you call.

When ice keeps coming back

A one-off drift after a storm is common. Ice that forms on the same terminal after every cold snap is a different problem. It can mean the vent is in a bad spot (under a deck, on a wall that takes the prevailing wind, or where a roof dumps melt water), the pipe does not slope the way it should, or exhaust is drifting back toward the intake and freezing there. Those are installation or drainage issues, not something you can fix with a broom.

The condensate line inside the house can also give trouble in a cold snap. The water that a condensing furnace makes has to reach a drain or a condensate pump. If that line is blocked, frozen or disconnected, the furnace may shut down, and you may see water around the unit. Do not bypass a safety switch to keep the heat on. Call us and we will find the blockage and put the drain back the way it should be.

If this happens more than once in a winter, a visit is worthwhile even after the heat is back. We can check the venting, the slope of the pipes, the termination and the condensate drain, and tell you what would actually stop it from repeating.

If you have no heat now

During regular hours (Monday to Friday, 9 AM to 5 PM), a service call is $150 + tax and includes a diagnosis and a quote before any repair work begins. Urgent no-heat calls in those hours are still the regular $150 + tax rate. After-hours emergency calls — evenings, weekends and holidays — are $300 + tax. You can book online or call 613-862-5551. We handle no-heat calls across Ottawa, including Barrhaven and Stittsville, and after hours through our emergency HVAC service.

While you wait, keep any fuel-burning appliances’ vents in view after the next snowfall, and make sure your carbon monoxide alarms are working. Since January 1, 2026, Ontario’s Fire Code requires CO alarms next to sleeping areas and on every storey of a house that has a fuel-burning appliance, a fireplace or an attached garage.

Frequently asked questions

Why did my furnace stop after a snowfall?

On a high-efficiency furnace, the plastic intake and exhaust pipes usually exit a side wall. Snow or ice over either opening is a common reason the furnace shuts itself off. Check that the pipes are clear, as long as you can do it safely from the ground.

Can I clear the furnace vent myself?

Yes, if you do not smell gas and the carbon monoxide alarm has not sounded. Gently clear loose snow from around the openings. Do not hit, pry or chip the pipes. If they are iced solid, or the furnace will not stay running after you clear them, call us.

Is a blocked vent a carbon monoxide risk?

A blocked vent is a serious issue, which is why the furnace is designed to shut down. Health Canada says to inspect exhaust vents during and after snowstorms. If you smell gas, leave and call Enbridge or 911. If a CO alarm sounds, get everyone outside and call 911.

What if ice keeps forming on the pipes?

Recurring ice can mean a poor termination location, a pipe that does not slope correctly, or exhaust drifting back toward the intake. That needs a technician, not another round of clearing.

How much is a no-heat call?

A regular-hours service call (Monday to Friday, 9 AM–5 PM), including urgent no-heat calls in those hours, is $150 + tax. After-hours emergency calls are $300 + tax.