Heat pumps

How a Dual-Fuel Heat Pump Switches to the Furnace in Ottawa

Outdoor heat pump on a raised stand beside high-efficiency furnace vent pipes on a snowy house

A dual-fuel, or hybrid, system uses a heat pump for most of the year and a gas furnace when it gets very cold. The useful part is the switchover setting — and it should be chosen for your house, not copied from a neighbour.

What a dual-fuel system actually does

In a hybrid setup, an electric air-source heat pump handles heating and cooling for most of the year, and a gas furnace takes over on the coldest days. That is how we describe it on our heat pumps page, and it is a common choice for Ottawa homes that already have natural gas. Natural Resources Canada uses the same idea: the heat pump can be added to an existing system, for example when you replace a central air conditioner, and the furnace stays as the supplemental heat source.

The two do not run at the same time. Natural Resources Canada is explicit that in a hybrid system, either the heat pump operates or the furnace does. A control — usually a thermostat that supports dual-fuel, plus an outdoor temperature sensor — decides which one is on. That is why a new heat pump often needs a compatible thermostat. Our thermostats and controls page notes that not every smart thermostat works with every system, and that heat pumps and dual-fuel systems need a model that supports them. Some also need a common (“C”) wire. We check compatibility before we install.

The three temperatures that matter

Natural Resources Canada says most air-source systems are set to shut off or hand off at one of three temperatures, and that your installer can set them:

  • Thermal balance point. The outdoor temperature below which the heat pump no longer has enough capacity to heat the house on its own. Below that point, you need supplemental heat or the house falls behind.
  • Economic balance point. The temperature below which, given the price of electricity and natural gas, it costs less to run the furnace than the heat pump. This point moves when energy prices change.
  • Cut-off temperature. The heat pump’s own minimum operating temperature. Natural Resources Canada notes that for newer models this often falls between -15°C and -25°C. Below that, the heat pump cannot run, and the furnace has to carry the load.

Those three numbers are not the same, and they should not be treated as one generic “Ottawa setting.” A tight, well-insulated house with a properly sized cold-climate heat pump has a lower thermal balance point than a leaky house with a smaller unit. Our post on what size furnace or heat pump you need explains why that starts with a heat-loss calculation, not a guess from the old equipment.

How the setting should be chosen

A switchover that is too high — handing off to the furnace on a mild winter evening — means you burn gas on days the heat pump could still heat the house efficiently. A switchover that is too low can leave the heat pump struggling, with rooms that never quite catch up, or with the system cycling in and out of backup. The right starting point is the thermal and economic balance points for your equipment and your rates, then a comfort check after the first stretch of real cold.

After the first real cold snap, it is worth asking us to review the setting against how the house actually felt. A small change in the lockout can be the difference between a furnace that barely runs and one that comes on every evening. If you still have last winter’s gas and electricity bills, bring them; they help when we look at the economic balance point.

It is also worth knowing that a hybrid system is not your only backup option. Natural Resources Canada describes all-electric setups that use resistance elements or baseboards, which can run at the same time as the heat pump. Many Ottawa homes on gas still choose dual-fuel because the furnace is already there and it has plenty of output on a -25°C night. If you are still comparing a furnace, a heat pump and a hybrid system, our post on heat pump vs furnace vs hybrid walks through the trade-offs.

Some energy-efficiency programs need paperwork, and some require pre-approval before equipment is installed, so read the current rebates page before you buy. We can help with that paperwork, but the rules belong to the programs themselves.

What you can check at home

If you already have a dual-fuel system and you are not sure what it is doing on a cold day, start with the thermostat. Look for a setting such as “auxiliary heat,” “emergency heat,” an outdoor temperature lockout, or a dual-fuel switchover. Do not change it just to experiment on a -20°C night. If the display is confusing, or the house is uncomfortable, we can read the setting, explain it, and adjust it against your equipment.

Also check the obvious comfort issues first: a dirty filter, closed supply or return grilles, and a thermostat that was bumped into a mode that locks out the heat pump. If rooms are uneven, the problem may be ducts or air leakage rather than the switchover number. Natural Resources Canada notes that heat pumps usually move more air at a lower supply temperature than a furnace, so the existing ducts have to be able to handle that airflow.

To have the setting checked or to talk about adding a heat pump to your furnace, book online or call 613-862-5551. Regular hours are Monday to Friday, 9 AM to 5 PM, with a $150 + tax service call. After-hours emergency calls are $300 + tax. We do this work across Ottawa, including Kanata and Nepean.

Frequently asked questions

What is a dual-fuel or hybrid heat pump system?

It is a heat pump paired with a gas furnace. The heat pump handles heating and cooling most of the year, and the furnace takes over in deep cold. Natural Resources Canada notes that in a hybrid system, the two do not run at the same time.

What temperature should the system switch to the furnace?

There is no single Ottawa number. The setting should reflect the thermal balance point (when the heat pump can no longer heat the house on its own), the economic balance point (when the furnace is cheaper to run), and the heat pump’s cut-off temperature. Your installer can set those.

Can I use any smart thermostat?

Not always. Heat pumps and dual-fuel systems need a thermostat that supports them, and some need a common (“C”) wire. We check compatibility before we install.

Will the heat pump still work on a very cold night?

A modern cold-climate model can keep running in sub-zero weather when it is properly sized, but every heat pump has a minimum operating temperature. Below that, or below the switchover you have set, the furnace takes over.

Can you add a heat pump to my existing furnace?

Yes. That is a common dual-fuel setup, especially when a central air conditioner is due for replacement. We size it with a heat-loss calculation and quote the work before we start.

Sources

Sources last checked November 2026. Programs, rules and prices change; always confirm on the official website.

Need help? Call 613-862-5551 or book online. Regular hours Mon–Fri 9 AM–5 PM · Emergency service 24/7.

‹ Back to the blog

Call Book